核电站换料水箱底板缺陷检修工艺研究

Research on the Maintenance Technology for Defects of the Bottom Plate of theRefueling Water Tank in Nuclear Power Plant

  • 摘要: 换料水箱底板渗漏已逐渐成为核电站的共性问题。该文首先介绍了核电站换料水箱泄漏背景及结构,并阐述了同类水箱泄漏原因、常见泄漏形式以及目前常用的查漏方法;然后针对目前无法准确、全面排查漏点等问题,提出了三种改进优化的查漏方法,包括:新增反渗法泄漏检测工艺、真空盒显现法工艺以及正压吸枪法氦检工艺,并详细分析了三种改进优化的查漏方法在换料水箱底板查漏中的优势及应用效果;最后对底板缺陷类型及产生原因进行分析,明确了采用贴板方式是现阶段返修较为有效手段,同时提出了后续需进一步研究和优化的方向。

     

    Abstract: Leakage from the refueling water tank bottom plate has gradually become a common issue in nuclear power plants. This paper first introduces the background and structural characteristics of refueling water tank leakage in nuclear power plants and explains the causes, common leakage forms, and currently used leak detection methods. Then, to address the existing problems of inaccurate and incomplete leak point identification, three improved and optimized leak detection methods are proposed: the reverse infiltration detection method, the vacuum box display method, and the positive pressure suction gun helium detection method. The advantages and application effects of these three improved leak detection methods in detecting leaks in refueling water tank bottom plates are analyzed in detail. Finally, the types and causes of bottom plate defects are discussed, and it is clarified that the plate-attaching repair method is currently the most effective means of rework. Directions for further research and optimization are also proposed.

     

/